Description
CliUtils#handleSigInt() introduced with OAK-2171 uses sun.misc.Signal and sun.misc.SignalHandler to gracefully shut down after e.g. Ctrl+C.
Instead of using internal and sun specific APIs, this should be implemented using a shutdown hook.